Maternal and fetal outcomes in meconium-stained amniotic fluid deliveries in a tertiary center
DOI:
https://doi.org/10.56056/amj.2022.170Keywords:
Meconium-stained amniotic fluid, Meconium aspiration syndrome, Maternal outcomes; Fetal outcomesAbstract
Backgrounds and objectives: Meconium -stained liquor could be an alarming sign of fetal distress and needs continuous fetal heart rate monitoring and urgent interventions. The study aimed to determine maternal and fetal outcomes among women presented with meconium-stained amniotic fluid during labor in relation to mode of delivery, rate of caesarian section, Admission to neonatal intensive care unit and neonatal complications and mortality.
Methods: A cross-sectional study was carried out in Duhok Obestetric and Gynecology Teaching Hospital between 1st of September 2019 and 1st of April 2020 where 100 women in labor diagnosed with meconium stained amniotic fluid gestational age between (37_40+6 weeks) included in this study, all participants were meet inclusion criteria for this study and a written consent obtained from them.
Results: The study showed that out of 100 participants with meconium stained liquor 48% of them delivered by lower segment cesarean section and the cause of 76.6% of them was fetal distress .The study showed significant statistical association between meconium stained liquor and lower mean scores of APGAR scores at 1 and 5 min , and rate of neonatal intensive care unit admission which was 74 (74.0%) and neonatal complications rate such as meconium Aspiration Syndrome (31.0%), Respiratory Distress Syndrome (14.0%), and Early Neonatal Death (3.0%) ,the study showed that women with spontaneous rupture membrane and thick meconium were significantly more likely to have infants with meconium aspiration syndrome; 46.2% and 48.1% respectively.
Conclusions: This study showed that women in labor with meconium-stained amniotic fluid had higher fetal and maternal complications.
Downloads
References
Cunningham F, Leveno K, Bloom S et al. Preconceptional counseling. Williams Obstetrics.25th edition, New York McGraw-Hill Education / Medical, 2019. p. 194.
Qadir S, Jan S, Chachoo J, Parveen S. Perinatal and neonatal outcome in meconium stained amniotic fluid. Int J Reprod Contracept Obstet Gynecol. 2017;5(5):1400-5.
Pierce J, Gaudier FL, Sanchez-Ramos L. Intrapartum amnioinfusion for meconium-stained fluid: meta-analysis of prospective clinical trials. Obstet Gynecol. 2000;95(6):1051-6.
Unnisa S, Sowmya B, Rao S, Rajagopal K. Maternal and fetal out come in meconium stained amniotic fluid in a tertiary centre. Int J Reprod Contracept Obstet Gynecol. 2016;5(3):813-17.
Jain PG, Sharma R, Bhargava M. Perinatal outcome of meconium stained liquor in pre-term, term and post-term pregnancy. Indian J Obstet Gynecol Res. 2017;4(2):146-50.
Mundhra R, Agarwal M. Fetal outcome in meconium stained deliveries. J Clin Diagn Res. 2013;7(12):2874-76.
Khatun MHA, Arzu J, Haque E. Fetal outcome in deliveries with meconium stained liquor. Bangladish J Child Health. 2009;33(2):41-5.
Halle-Ekane G, Fon P, Koki P, Tazinya A, Ekollo R, Mboudou E. Maternal and Perinatal Outcomes in Childbirths with Meconium Stained Amniotic Fluid in a Low-resource Setting: A Prospective Cohort Study. ACRI. 2019:1-11.
Maymon E, Chaim W, Furman B, Ghezzi F, Vardi IS, Mazor M. Meconium stained amniotic fluid in very low risk pregnancies at term gestation. EJOG. 1998;80(2):169-73.
Mohammad N, Jamal T, Sohaila A, Ali S. Meconium stained liquor and its neonatal outcome. Pak J Med Sci. 2018;34(6):1392.
Anwar Z, Butt TK, Kazi M. Mortality in meconium aspiration syndrome in hospitalized babies. J Coll Physicians Surg Pak. 2011;21(11):695-9.
Sasikala A, Raghavan S, Mishra N, Khatoon S, Bupathy A, Rani R. Perinatal outcome in relation to mode of delivery in meconium stained amniotic fluid. Indian J Pediatr. 1995;62(1):63-7.
Naqvi SB, Manzoor S. Association of meconium stained amniotic fluid with perinatal outcome in pregnant women of 37-42 weeks gestation. Pak J Surg. 2011;27(4):292-8.
Committee on Obstetric Practice. Committee Opinion No 689: Delivery of a Newborn with Meconium-Stained Amniotic Fluid. Obstet Gynecol. 2017;129(3): e33
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Payman Ghiyath Al-deen Abdulghafor, Maida Yousif Shamdeen, Khalida Hassan Muho
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
The copyright on any article published in AMJ (The Scientific Journal of Kurdistan Higher Council of Medical Specialties )is retained by the author(s) in agreement with the Creative Commons Attribution Non-Commercial ShareAlike License (CC BY-NC-SA 4.0)